Shielding Effectiveness Measurements: traditional system vs SEMS and calibration criteria

The SEMS (Shielding Effectiveness Measurement System) has been designed by MPB to perform attenuation measurements of Faraday cages in the frequency range from 10 kHz to 300 MHz.

The system consists of two units:

  • TX Unit (transmitter);
  • RX Unit (receiver).

The fully automatic system allows shielding effectiveness measurements to be performed with no possibility for the operator to modify the output data. This ensures high reliability and excellent repeatability of the results.

The procedure is divided into two phases.

Phase 1 - System zeroing

In this phase, initial calibration is carried out by characterizing the entire transmission/reception path without any shielding element between the transmitting and receiving antennas.

Phase 2 - Measurement with shielding in place

The shielding material (Faraday cage or shielded enclosure) is then placed between the antennas. In fully automatic mode, the receiver measures the transmitted signal attenuated by the shielding. The measured value is compared with Phase 1 and processed to determine the shielding attenuation.

SEMS B system for measuring shielding effectiveness of Faraday cages, anechoic and semi-anechoic chambers and military shelters


Due to its operating principle, SEMS is classified as a relative measurement system, not an absolute one.

The final result is obtained from the difference between two measurements. It represents a relative value (attenuation introduced by the shielding), not an absolute measurement referenced to a metrological standard. Therefore, ISO/IEC 17025 accredited calibration is not applicable to the SEMS system as a whole.

Similarly, traditional systems (RF generator, amplifier, spectrum analyzer) used according to the IEEE 299 standard also rely on relative measurements between reference and shielded conditions.

Traditional RF measurement system with generator, amplifier and spectrum analyzer


Metrological traceability is ensured through calibration of the individual instruments in the measurement chain and the equipment used to verify system performance. SEMS undergoes functional calibration using reference instruments with ISO/IEC 17025 accredited certificates issued by accredited laboratories.

Contacts

MPB S.r.l.
Via Giacomo Peroni 400/402
Polo Tecnologico Tiburtino
00131 Roma RM

Phone:
+390641200744
Fax:
+390641200653
E-mail:
info@mpbelectronic.com

Associated products

MPB B1-N biconical antenna

ANTENNAS

B1-N

MPB-CAL-KIT-Attenuator

RF TEST

CAL-KIT

MPB L2-P 1

ANTENNAS

L2-P

MPB NMR-01 1

NON MAGNETIC SUPPORT

NMR-01

MPB D-2 1

ANTENNAS

D-2

MPB L1-P 1

ANTENNAS

L1-P

MPB L-3 1

ANTENNAS

L-3

logo MPB S.r.l.
MPB srl

Via Giacomo Peroni 400/402
00131 Roma (RM)
Tel: +39 0641200744
Fax: +39 0641200653
P.IVA: 05415291003
Pec: mpb_srl@pec.it
RAEE: IT24070000016275

Company info

C.F. and Registration number in the company register of the Court of Rome: 05415291003
Share capital euros 100.000,00 Int. vers.
REA 887876

Social

©2026 MPB S.r.l. All rights reserved.