The IEC 61000-4-6 is the international standard that defines conducted immunity tests for disturbances induced by radio-frequency (RF) fields.
Its purpose is to verify that electrical and electronic devices continue to operate correctly even when simulated RF voltages, similar to those that may occur in real disturbed environments, are present on their power or signal lines.
The test falls within the IEC 61000-4 series, which is dedicated to electromagnetic compatibility (EMC) testing methods, and complements:
Applications fields
IEC 61000-4-6 applies to any device that has at least one cable connection (power, signal, or communication). The frequency range covered goes from 150 kHz a 80 MHz, extendable up to 230 MHz in specific cases.
Completely isolated devices, those without any connection that could act as a coupling path for conducted disturbances, are excluded.
Purpose of the test
The purpose is to simulate the effects of RF conducted fields on equipment cables and verify that the Equipment Under Test (EUT) maintains correct operation.
The disturbance, a slowly varying 1 kHz-modulated RF signal, is generated by an RF source with AM 1 kHz, 80% modulation and injected into the cables using coupling devices such as:
During the test, the device must continue to operate without failures or abnormal behavior.

Test Severity Levels
IEC 61000-4-6 defines four severity levels, expressed as RMS injected voltage:
| Level | Voltage (RMS) | Typical Environment |
| 1 | 1 V | Residential or low exposure |
| 2 | 3 V | Commercial or office |
| 3 | 10 V | Industrial or noisy areas |
| X | custom | Defined by manufacturer |
Each level represents increasing disturbance intensity.The device must meet performance criteria A, B, C, or D as defined in the standard.
Test setup and required equipment
The test setup for IEC 61000-4-6 typically includes:
Proper calibration of the injection level is essential to ensure repeatable and compliant results.
RF Amplifiers for IEC 61000-4-6 testing
Recommended RF amplifier solutions include:
Band: 9 kHz – 250 MHz | Power: 250 W | Gain: 51 dB
Ideal for IEC 61000-4-6 testing and multi-purpose EMC setups.
For IEC 61000-4-3 radiated immunity tests:
Band: 27 – 1000 MHz | Power: 500 W | Gain: 54 dB
Suitable for laboratories performing extended EMC test ranges.
Both amplifiers offer stability, linearity, and reliability under variable load conditions, ensuring consistent and repeatable test results.
Acceptance Criteria
During conducted immunity testing, the EUT is evaluated according to the following criteria:
| Criterion | Description |
| A | Normal operation without degradation |
| B | Temporary degradation, with automatic recovery |
| C | Loss of function requiring manual intervention |
| D | Permanent damage or loss of function |
IEC 61000-4-6 is one of the key standards for verifying immunity to RF conducted disturbances. With a broad range of RF solutions designed to meet different testing and regulatory requirements, MPB supports EMC laboratories in performing accurate, compliant tests and ensuring conformity to international standards.
ISO 17025 and accredited calibration: what it really means in the context of electromagnetic fields
In the field of electromagneti...
Smoke Detection in MRI Rooms: Fiber Optic Systems for EMI-Free Fire Safety
Smoke detection in magnetic re...
Shielding Effectiveness Measurements: traditional system vs SEMS and calibration criteria
The SEMS (Shielding Effectiven...
CISPR 16-1-4: practical guide to EMC site validation
In the field of electromagneti...
MPB Supports Advanced Training in Radioprotection with ANPEQ – Piacenza, February 4–6, 2026
Continuous training has always...
MPB S.r.l.
Via Giacomo Peroni 400/402
Polo Tecnologico Tiburtino
00131 Roma RM

Via Giacomo Peroni 400/402
00131 Roma (RM)
Tel: +39 0641200744
Fax: +39 0641200653
P.IVA: 05415291003
Pec: mpb_srl@pec.it
RAEE: IT24070000016275
C.F. and Registration number in the company register of the Court of Rome: 05415291003
Share capital euros 100.000,00 Int. vers.
REA 887876
©2026 MPB S.r.l. All rights reserved.